Event Forwarding
Security Requirements and Controls
Change event forwarding
permission
Event forwarding is used to forward events that are ingested into LogScale to other systems that require parts of the data for e.g. Machine Learning, while still logging everything in a central place.
Currently, forwarding is done using Kafka.
Figure 94. Event Forwarding
When data shipper is Ingesting Data, it is first parsed. Then it is stored in a repository in LogScale and sent through any Event Forwarding Rules on the repository, which can filter and transform the events before forwarding them to an external system through an Event Forwarders.
Note
If you ingest events with timestamps older than your retention policy allows, the data will be forwarded without being stored in LogScale.
Configuration
Event forwarding is configured in two steps. First, an Event Forwarders is created that defines a Kafka server and topic to forward the events to. Second, one or more Event Forwarding Rules are configured on the repositories, where events should be forwarded from, and connected to the event forwarders.
You must enable event forwarding in the configuration using
ENABLE_EVENT_FORWARDING
.
Event Forwarding Format
Events are sent as one event per message. The format is JSON where every field is a top-level element, and all field values are returned as JSON strings, except for @timestamp, which is returned as a number representing time as Unix time in milliseconds (UTC/Zulu time).
Error Handling
There are no delivery guarantees on event forwarding. This means, that if forwarding an event fails, LogScale will neither retry later nor fail the ingest. This is done in order to not impact ingest.
Note
A failure during parsing does not necessarily mean a failure during forwarding. As described in the Parser Errors documentation, this will simply set a number of fields to error values, such as @event_parsed = false. Unless filtered out by the forwarding rule (using e.g. @event_parsed != false), these events will still be forwarded.
LogScale will only log that event forwarding failed if multiple events fail to be forwarded, in order not to spam the logs. The number of events that failed to be forwarded can be seen in the metric event-forwarding-errors. See LogScale Metrics.
LogScale uses
circuit
breakers to prevent event forwarding errors from affecting the
performance and stability of LogScale. The
circuit breakers can be configured using the configuration options that
have the FORWARDING_BREAKER_
prefix.
LogScale also enforces a limit on the number of events concurrently
waiting to be forwarded. This is to prevent events exhausting memory due
to a stuck/blocked forwarder. This limit can
be changed by setting
FORWARDING_MAX_CONCURRENCY
.